BIOAQUA

Ventilator Compatible Humidifier

13

Invasive, Non-Invasive and HFNC

Optimized performance across all respiratory therapies

12

Integrated Nebulizer

Ensures uninterrupted aerosol drug delivery

14

Adult, Pediatric and Neonatal

Adapted for patients of all ages

4-02

Visual and Audible Alarms

Enhanced safety with real-time alerts

Bioaqua is a medical humidifier developed to protect the respiratory tract in critical patient care.

The device heats and humidifies medical gases to prevent cold and dry air from damaging the respiratory epithelium.

During invasive, non-invasive, or high-flow oxygen therapy, Bioaqua delivers inhaled air at optimal temperature and humidity levels.

With its integrated nebulizer, it stands out from other humidifiers by offering more advanced and effective treatment solutions. It is suitable for all patient groups, including neonatal, pediatric, and adult patients.

bioaqua | ventilator compatible humidifier
bioaqua | ventilator compatible humidifier

Advanced humidification,

maximum comfort.

Comparison Chart

The table below compares various brands’ Intensive Care Humidifiers with the Bioaqua Ventilator Compatible Humidifier.

Responsive Table
ABC
Patient TypeNeonatal, Pediatric and AdultNeonatal, Pediatric and AdultNeonatal, Pediatric and AdultChild and Adult
Flow RateIntubation Mode: 2-60L/m
Mask Mode: 2-120L/m
Intubation Mode: 60L/m
Mask Mode: 120L/m
Intubation Mode: 5L/m
Mask Mode: 25L/m
Intubation Mode: 5-60L/m
Mask Mode: 5-120L/m
Universal Chamber
me
me
me
me
Temperature SettingBetween 30°C to 40°C + off,
11 different temperature level :
Invasive mode: 35°C - 40°C
Non-Invasive mode: 30°C - 35°C
HFO mode: 30°C - 37°C
Invasive mode:
Chamber: 35.5 - 42°C,
Airway: 35- 40°C

Non-invasive
Chamber: 31 - 36°C,
Airway 28 - 34°C
Intubation Mode;
Water Tank: 35.5-420°C
By Air: 35-400°C

Mask Mode;
Water Tank: 31-360°C
Airline: 28-340°C
Test Working Temperature: 18°C ~ 26°C
Temperature of inlet gas: 18°C ~ 26°C
Nebulizer Therapy
me
me
me
me
Alarm ParametersLow Temperature
High Temperature
Temperature Probe Not Plugged
Breathing Circuit Not Plugged
Chamber Not Connected
Nebulizer Not Connected
Overheat
Flow
Chamber Empty
High Temperature
Low Temperature
Chamber or Airway Probe
Probe Connector
Heater Wire
Operational Alarms
High-temperature
Protection Cut-Off Function
High Temperature
Low Temperature
Low Humidity
Over-filled Chamber
Dry Humidification Chamber
Wrong Installation Chamber
Lower limit of gas level
Has NIV,INV,HFO and
Free Parameter Settings
me
me
me
me
Screen3.5" touchscreen
and control button
3 digit 14mm
7 segment LED
2.8" touchscreen2.8" TFT and Control Buttons
Ergonomic and
Intuitive User Interface
me
me
me
me
Heating TimeLess than 30 min.Less than 30 min.Less than 25 min.
Shelf Life10 Years7 YearsNo Shelf LifeNo Shelf Life

Product Comparison

Bioaqua
Patient Type
Neonatal, Pediatric and Adult
Flow Rate
Intubation: 2-60L/m
Mask: 2-120L/m
Universal Chamber
Yes
Temperature Setting
30°C–40°C + off
11 levels:
Invasive: 35–40°C
Non-invasive: 30–35°C
HFO: 30–37°C
Nebulizer Therapy
Yes
Alarm Parameters
Low/High Temperature
Probe Not Plugged
Breathing Circuit Not Plugged
Chamber/Nebulizer Not Connected
Overheat · Flow
NIV/INV/HFO Settings
Yes
Screen
3.5" Touchscreen + Control Button
Intuitive Interface
Yes
Heating Time
Less than 30 min.
Shelf Life
10 Years
Product A
Patient Type
Neonatal, Pediatric and Adult
Flow Rate
Intubation: 60L/m
Mask: 120L/m
Universal Chamber
Yes
Temperature Setting
Invasive:
Chamber: 35.5-42°C, Airway: 35-40°C

Non-invasive:
Chamber: 31-36°C, Airway: 28-34°C
Nebulizer Therapy
No
Alarm Parameters
Chamber Empty
High/Low Temperature
Chamber or Airway Probe
Probe Connector
Heater Wire
Operational Alarms
NIV/INV/HFO Settings
No
Screen
3 digit 14mm 7 segment LED
Intuitive Interface
No
Heating Time
Less than 30 min.
Shelf Life
7 Years
Product B
Patient Type
Neonatal, Pediatric and Adult
Flow Rate
Intubation: 5L/m
Mask: 25L/m
Universal Chamber
No
Temperature Setting
Intubation:
Water Tank: 35.5-42°C, By Air: 35-40°C

Mask:
Water Tank: 31-36°C, Airline: 28-34°C
Nebulizer Therapy
No
Alarm Parameters
High Temperature
Protection Cut-Off Function
NIV/INV/HFO Settings
Yes
Screen
2.8" Touchscreen
Intuitive Interface
Yes
Heating Time
Shelf Life
No Shelf Life
Product C
Patient Type
Child and Adult
Flow Rate
Intubation: 5-60L/m
Mask: 5-120L/m
Universal Chamber
No
Temperature Setting
Test Working Temp: 18°C–26°C
Inlet gas temp: 18°C–26°C
Nebulizer Therapy
No
Alarm Parameters
High/Low Temperature
Low Humidity
Over-filled Chamber
Dry Humidification Chamber
Wrong Installation
Lower limit of gas level
NIV/INV/HFO Settings
No
Screen
2.8" TFT and Control Buttons
Intuitive Interface
No
Heating Time
Less than 25 min.
Shelf Life
No Shelf Life

Enquire about the BIOAQUA ICU Humidifier

If you have an enquiry about our products, please provide the following information so a Biosys representative can contact you.