BIOAQUA
Ventilator Compatible Humidifier
Invasive, Non-Invasive and HFNC
Optimized performance across all respiratory therapies
Integrated Nebulizer
Ensures uninterrupted aerosol drug delivery
Adult, Pediatric and Neonatal
Adapted for patients of all ages
Visual and Audible Alarms
Enhanced safety with real-time alerts
Bioaqua is a medical humidifier developed to protect the respiratory tract in critical patient care.
The device heats and humidifies medical gases to prevent cold and dry air from damaging the respiratory epithelium.
During invasive, non-invasive, or high-flow oxygen therapy, Bioaqua delivers inhaled air at optimal temperature and humidity levels.
With its integrated nebulizer, it stands out from other humidifiers by offering more advanced and effective treatment solutions. It is suitable for all patient groups, including neonatal, pediatric, and adult patients.


Advanced humidification,
maximum comfort.

Comparison Chart
The table below compares various brands’ Intensive Care Humidifiers with the Bioaqua Ventilator Compatible Humidifier.
![]() | A | B | C | |
|---|---|---|---|---|
| Patient Type | Neonatal, Pediatric and Adult | Neonatal, Pediatric and Adult | Neonatal, Pediatric and Adult | Child and Adult |
| Flow Rate | Intubation Mode: 2-60L/m Mask Mode: 2-120L/m | Intubation Mode: 60L/m Mask Mode: 120L/m | Intubation Mode: 5L/m Mask Mode: 25L/m | Intubation Mode: 5-60L/m Mask Mode: 5-120L/m |
| Universal Chamber | ![]() | ![]() | ![]() | ![]() |
| Temperature Setting | Between 30°C to 40°C + off, 11 different temperature level : Invasive mode: 35°C - 40°C Non-Invasive mode: 30°C - 35°C HFO mode: 30°C - 37°C | Invasive mode: Chamber: 35.5 - 42°C, Airway: 35- 40°C Non-invasive Chamber: 31 - 36°C, Airway 28 - 34°C | Intubation Mode; Water Tank: 35.5-420°C By Air: 35-400°C Mask Mode; Water Tank: 31-360°C Airline: 28-340°C | Test Working Temperature: 18°C ~ 26°C Temperature of inlet gas: 18°C ~ 26°C |
| Nebulizer Therapy | ![]() | ![]() | ![]() | ![]() |
| Alarm Parameters | Low Temperature High Temperature Temperature Probe Not Plugged Breathing Circuit Not Plugged Chamber Not Connected Nebulizer Not Connected Overheat Flow | Chamber Empty High Temperature Low Temperature Chamber or Airway Probe Probe Connector Heater Wire Operational Alarms | High-temperature Protection Cut-Off Function | High Temperature Low Temperature Low Humidity Over-filled Chamber Dry Humidification Chamber Wrong Installation Chamber Lower limit of gas level |
| Has NIV,INV,HFO and Free Parameter Settings | ![]() | ![]() | ![]() | ![]() |
| Screen | 3.5" touchscreen and control button | 3 digit 14mm 7 segment LED | 2.8" touchscreen | 2.8" TFT and Control Buttons |
| Ergonomic and Intuitive User Interface | ![]() | ![]() | ![]() | ![]() |
| Heating Time | Less than 30 min. | Less than 30 min. | — | Less than 25 min. |
| Shelf Life | 10 Years | 7 Years | No Shelf Life | No Shelf Life |
Product Comparison
Mask: 2-120L/m

11 levels:
Invasive: 35–40°C
Non-invasive: 30–35°C
HFO: 30–37°C

Probe Not Plugged
Breathing Circuit Not Plugged
Chamber/Nebulizer Not Connected
Overheat · Flow


Product A
Mask: 120L/m

Chamber: 35.5-42°C, Airway: 35-40°C
Non-invasive:
Chamber: 31-36°C, Airway: 28-34°C

High/Low Temperature
Chamber or Airway Probe
Probe Connector
Heater Wire
Operational Alarms


Product B
Mask: 25L/m

Water Tank: 35.5-42°C, By Air: 35-40°C
Mask:
Water Tank: 31-36°C, Airline: 28-34°C

Protection Cut-Off Function


Product C
Mask: 5-120L/m

Inlet gas temp: 18°C–26°C

Low Humidity
Over-filled Chamber
Dry Humidification Chamber
Wrong Installation
Lower limit of gas level